Built for the district office, not the demo room.
Capture devices, enrolment kits and verification terminals for 45°C, airborne dust, four hours of mains power and an engineer 400 kilometres away.

Failure to enrol is the outcome that matters, and it is settled at the moment of capture — by optics, pressure guidance, ambient light rejection and the quality feedback the operator sees. Not by the matcher downstream.
Published accuracy figures are measured in laboratories on cooperative subjects. They tell you very little about a market town at midday with a queue of agricultural workers whose fingerprints have been worn flat by thirty years of work. Multiply a few percent of failure across a national population and it stops being a technical issue and becomes a political one.
Single-finger scanners
Verification at service counters, agent points and border desks.
Ten-print and slap scanners
Enrolment-grade capture for deduplication galleries.
Iris capture
Single and dual-eye, for populations where fingerprint quality is poor.
Face capture
ICAO-compliant portrait capture with live quality validation and presentation-attack detection.
Field enrolment kits
Capture devices, laptop, signature pad, document scanner, printer, battery and solar interface in a ruggedised case. Deployable by two people in under 20 minutes.
Verification terminals
Fixed and handheld, for borders, polling stations, clinics and payment agents. Online and offline.
Issuance peripherals
Card printers, laminators, document scanners and signature pads, qualified as a matched set with the capture devices.
- 01
Site profile
Temperature, humidity, dust, ambient lighting, power availability, connectivity, throughput target, operator skill level.
- 02
Population profile
Age distribution, occupation, known capture difficulties. This is where fingerprint quality problems become predictable rather than discovered at scale.
- 03
Shortlist against standards
ISO/IEC 19794 output, exposed NFIQ 2.0 quality scores, PAD conformance, SDK platform coverage, environmental ratings.
- 04
Field trial
Candidate devices tested against a sample of your population in representative conditions. Failure-to-enrol and capture-quality distributions measured, not assumed.
- 05
Qualification report
A written comparison with the data behind it, and a recommendation. You keep the report either way.
Heat
Specified operating range with headroom, and continuous rather than factory-once calibration where sensors drift with temperature.
Dust and moisture
Sealed optics, rated enclosures, and platens cleanable in the field with what is actually available there.
Power
Low draw, wide input tolerance, continued operation through voltage drops, and native battery and solar support.
No connectivity
Offline-first capture with a signed, encrypted local queue and store-and-forward sync. An operator never stops work because a link dropped.
Serviceability
Modular components a trained local operator can swap without tools, and remote diagnostics that work over a narrow link.
- SDKs for the platforms your application runs on — desktop, server and mobile — with common language bindings
- ISO/IEC 19794 and ANSI/NIST-ITL templates and retained raw images, so a future matcher migration remains possible
- Quality metrics surfaced to the application, so you enforce your thresholds rather than ours
- Presentation-attack detection per ISO/IEC 30107-3
- Fleet management: inventory, firmware, calibration status, health telemetry
- Native integration with our own enrolment and identity platform; documented integration with third-party ABIS platforms
- Volume availability and lead times confirmed per order against current stock and production
- An in-region spares pool sized to your uptime target, with a defined replacement policy
- Field support across our regions of operation in Europe, the Middle East, Africa and Asia Pacific, with exact country coverage confirmed per programme
- Standard warranty, with extended and on-site options
- Consumables: cleaning kits, platen film, card stock, ribbons, laminates
- Training: operator, technician, and train-the-trainer
Can we buy devices without buying a DNH system?
Yes, with full SDK access and standards-conformant output.
Will they work with our existing ABIS?
They emit ISO/IEC 19794 and ANSI/NIST-ITL, which is what a conforming ABIS ingests. We'll run an integration test against your platform before you commit to volume.
What if a better device appears mid-programme?
Because the output is standards-native, devices can be substituted without re-templating the gallery. That is the main practical reason to insist on conformance at procurement rather than accepting a proprietary format.
How do you handle firmware updates on offline devices?
Signed update packages applied from removable media by a local operator, with rollback if verification fails.
What's the minimum order?
Set per device category and configured to your programme volume. Evaluation units are available individually.
Tell us the modality, the site conditions and the throughput target. We'll ship evaluation units and run the qualification against a sample of your people.